wiki:Internal/Mapping/Calibration

Version 12 (modified by zhibinwu, 18 years ago) ( diff )

Internal → Calibration

WiFi Card Calibration

As the first important discovery in ORBIT testbed, some (if not most) WiFi cards behaved strangely. Therefore, it is really important to identify those bad cards. The calibration procedure tries to find if the Tx power and RSSI measurement of the card in each 802.11 channel is regular or not.

For each card, the calibration has two experiments:

  1. Card-RX exp: A standard signaling generator will generator 500 802.11 beacons in 5 seconds, the card has to report its measured RSSIs.
  2. Card-TX exp: A VSA equipment will measure 500 beacons generated by the card

Those experiments are going to be repeated in each 802.11 a/b/g channel and with 4 different Tx power levels: 1, 10, 20, 100mW.

Calibration Procedure

  1. Pick up one node from the grid and take it down from the shelf
  2. load baseline-calibration.ndz image to the node
  3. Connecting RF cable to one of the card
  4. ssh to console.grid
  5. ./caliber.pl [mac-addr]
  6. check the calibration_central database in idb1.
  7. Do above procedures for another card

Database Format

The database is named “calibration_central”. It is now in idb1. It has two tables:

  • Rx_caliber: has all measurements by Card-Tx experiment.
  • Tx_caliber: has all measurements by Card-Rx experiment.

Example table records

Rx_caliber

Card Mac address Date Time ESGTxPr channelRSSI
3F:65:89:4E:2D:0C 2006-07-07 12:29:15 10 6 45

Tx_caliber

Mac-address Date Time CardTxPr channel VSAreading
3F:65:89:4E:2D:0C 2006-07-07 12:30:21 100 11 65

For developers

Attachments (1)

Download all attachments as: .zip

Note: See TracWiki for help on using the wiki.