| 1 | | = Teltonika UM62x1 = |
| 2 | | |
| 3 | | [http://www.teltonika.lt/en/pages/view/?id=1010 Teltonika UM62x1] |
| 4 | | |
| 5 | | == How To's == |
| 6 | | |
| 7 | | === Linux === |
| 8 | | |
| 9 | | Device will look like a cdrom |
| 10 | | |
| 11 | | {{{ |
| 12 | | eject |
| 13 | | }}} |
| 14 | | |
| 15 | | If you install usb-modeswitch and usb-modeswitch-data then it will appear as a network interface and not USB storage by default, and you won't need to "eject" the device. |
| 16 | | |
| 17 | | |
| 18 | | Can use: |
| 19 | | |
| 20 | | {{{ |
| 21 | | wget --http-user admin --http-password admin -qO - http://192.168.0.1/cgi/cli?[command] |
| 22 | | }}} |
| 23 | | See data collection below for how to find a list of commands. |
| 24 | | |
| 25 | | === Embedded Linux === |
| 26 | | |
| 27 | | Verified working with Openwrt on Routerstation Pro. |
| 28 | | |
| 29 | | TODO: Complete kernel module list. |
| 30 | | Kernel has to be compiled with cdc_ether, scsi cdrom |
| 31 | | |
| 32 | | If using Openwrt, compile busybox with eject command or dmesg to find out what the device shows up as: |
| 33 | | |
| 34 | | {{{ |
| 35 | | opkg update |
| 36 | | opkg install sdparm |
| 37 | | sdparm --command=eject /dev/sg? |
| 38 | | }}} |
| 39 | | |
| 40 | | Then use the above Linux tutorial. |
| 41 | | |
| 42 | | === Windows === |
| 43 | | |
| 44 | | Verified working in Windows 7 64-bit |
| 45 | | |
| 46 | | Did not test without installing Teltonika software |
| 47 | | |
| 48 | | Install software when prompted to. |
| 49 | | |
| 50 | | === Mac OS === |
| 51 | | |
| 52 | | Verified working under Lion |
| 53 | | |
| 54 | | TODO. |
| 55 | | |
| 56 | | == Settings == |
| 57 | | |
| 58 | | After the device is set up, the USB device will appear as a wired Ethernet device with the, dhcp release, IP address of 192.168.0.x. |
| 59 | | |
| 60 | | 1. Favorite browser ==> 192.168.0.1 |
| 61 | | a. To login, press ctrl+shift and click on the Teltonika logo on the top of the web page. The default username for the administrative interface that we will be using is:[[BR]] |
| 62 | | Username: admin[[BR]] |
| 63 | | Password: EifAFKt8 |
| 64 | | |
| 65 | | 2. Configure Wimax |
| 66 | | a. Click on WiMAX tab |
| 67 | | b. Click on Channels sub-tab |
| 68 | | c. Add your base station(s) information |
| 69 | | 3. Verify connectivity |
| 70 | | |
| 71 | | Note that your settings are stored on the device, so this will only have to be done once for each device. |
| 72 | | |
| 73 | | == Telnet == |
| 74 | | 1. telnet 700 |
| 75 | | a. Notice that above the port is 700[[BR]] |
| 76 | | Username: admin[[BR]] |
| 77 | | Password: admin01 |
| 78 | | |
| 79 | | 2. To make change to files (At your own risk of making a paper weight): |
| 80 | | a. mount -o,remount,rw / |
| 81 | | |
| 82 | | == Data collection & Misc == |
| 83 | | |
| 84 | | One tab I would like to point out is the CLI (command line interface) that you can run several commands to collect all kinds of information. A list of commands can be viewed with the help command. There is also more options that you can get by typing in 'setuser su' and then type help. |
| 85 | | |
| 86 | | Output of help command (as Normal user): |
| 87 | | {{{ |
| 88 | | COMMAND HELP |
| 89 | | ============ |
| 90 | | CMD help Get help on commands |
| 91 | | RFC resetRfcSdcDbgStats reset rfcSdc dbg stats |
| 92 | | CBE showMacUl Show the MAC uplink configuration |
| 93 | | CBE showMacDl Show the MAC downlink configuration |
| 94 | | CBE showMacFrame Show the MAC frame configuration |
| 95 | | CBE showMacStatsRx Show MAC message reception statistics |
| 96 | | CBE showSsCaps Show negotiated capabilities of an SS |
| 97 | | CBE showCaps Show global capabilities |
| 98 | | CBE setCaps Set global capabilities |
| 99 | | CBE setHarqCategory Changes the *declared* HARQ category. |
| 100 | | CBE loadCalibrationFromHost Load calibration file from host |
| 101 | | CBE showSf Show SF information |
| 102 | | CBE createSf Declare a SF in the local SFD |
| 103 | | CBE changeSf Change a SF in the local SFD |
| 104 | | CBE deleteSf Delete a SF in the local SFD |
| 105 | | CBE setSfEnable Enable/disable a SF in the local SFD |
| 106 | | CBE showPhsSf Show PHS rules for Sf creation |
| 107 | | CBE createPhsSf Create/change PHS rules for Sf creation |
| 108 | | CBE deletePhsSf Delete PHS rules for Sf creation |
| 109 | | CBE setMii Set MII link configuration |
| 110 | | CBE showMii Show the MII configuration |
| 111 | | CBE showTime Show the current time |
| 112 | | CBE filterLog filter logging. Syntax is '(+/-)MOD[/SUB]'. '*' is supported at the end. |
| 113 | | CBE enableLog Enable logging. Syntax is 'MOD[/SUB]'. |
| 114 | | CBE disableLog Disable logging. Syntax is 'MOD[/SUB]'. |
| 115 | | CBE showLog show logging state. Syntax is 'MOD[/SUB]'. '*' is supported |
| 116 | | CBE suppressLogWarnings Enable/Disable warnings from disabled logs |
| 117 | | CBE enableSniffer enable packet sniffing |
| 118 | | CBE setSnifferVerbose set verbose level for the packet dumping |
| 119 | | CBE setSnifferParams set the sniffer parameters |
| 120 | | CBE disableSniffer disable packet sniffing |
| 121 | | CBE showSniffer show sniffer state and filters |
| 122 | | CBE clearSnifferFilters clear all sniffer filters |
| 123 | | CBE createSnifferFilter create a new sniffer filter |
| 124 | | CBE deleteSnifferFilter remove the specified filter from the sniffer |
| 125 | | CBE showMacAddress Show the mac address |
| 126 | | CBE setFatalErrorMode Set value of fatal error mode |
| 127 | | CBE showFatalErrorMode Show value of fatal error mode |
| 128 | | CBE showPkmCs Show pkm settings related to crypto suites |
| 129 | | CBE setPkmCs Set pkm settings related to crypto suites |
| 130 | | CBE showNeighborBs Display a neighbor BS descriptor from the handover database |
| 131 | | CBE showPsc Show the Power Saving Classes information |
| 132 | | CBE createPsc Declare a PSC in the local PSCD |
| 133 | | CBE changeSleepId Modify a PSC config |
| 134 | | CBE modifyPsc Modify a PSC config |
| 135 | | CBE deletePsc Delete a PSC from the PSC database |
| 136 | | CBE activatePsc Activate a PSC |
| 137 | | CBE deactivatePsc Deactivate a PSC |
| 138 | | CBES setQosRedUlDefaultProfile Configure the uplink RED drop profile for Sf without max latency |
| 139 | | CBES setQosRedUlMaxLatencyProfile Configure the uplink RED drop profile for Sf with non null max latency |
| 140 | | CBES setQosRedUlDefault Configure congestion control in uplink for Sf without max latency |
| 141 | | CBES showQosUl Show Ul Qos configuration |
| 142 | | CBES showSsPhyStatsDl display the downlink physical statistics |
| 143 | | CBES startSs start the 802.16 MAC |
| 144 | | CBES stopSs stop the 802.16 MAC |
| 145 | | CBES resetSs stop and restart the 802.16 MAC |
| 146 | | CBES showSs Show SS information |
| 147 | | CBES performHandover Jump to a neighbor BS (small cell jump) |
| 148 | | CBES requestPowerModeChange Request power control mode change |
| 149 | | CBES setTxPower Set TX power to specified value |
| 150 | | CBES setMaxTxPower set Max Tx Power |
| 151 | | CBES showSsAuth Show SS Authorization |
| 152 | | CBES resetSsAuth reset SS Authorization |
| 153 | | CBES showSa Show Security Association |
| 154 | | CBES showRfRx Show the radio frequency receiver configuration |
| 155 | | CBES showRfTx Show the radio frequency transmitter configuration |
| 156 | | CBES showRfConfig Show radio frequency configuration |
| 157 | | CBES showLinkAdaptationDl Show the downlink adaptation configuration |
| 158 | | CBES setLinkAdaptationDl Configures the downlink adaptation |
| 159 | | CBES showPhyStatsRx Show the downlink physical stats |
| 160 | | CBES setRfTx Set radio frequency / base band parameters for TX |
| 161 | | CBES showPacketFlow Show the packet flow statistics |
| 162 | | CBES resetPacketFlow Reset the packet flow statistics |
| 163 | | CBES showVersion Show the system version |
| 164 | | CBES setGpiosState Set the state of GPIO manager |
| 165 | | CBES setIdleMode Start IDLE mode |
| 166 | | CBES showProvisionedPsc Show the provisioned Power Saving Class config |
| 167 | | CBES setProvisionedPsc Set the full provisioned Power Saving Class config |
| 168 | | CBES modifyProvisionedPsc Modify some param of the provisioned Power Saving Class config |
| 169 | | CBES crashMeNow test delivery of fatals |
| 170 | | CBES sendRssiToHost test delivery of rssi level changes notifications to host via THP |
| 171 | | CBES enableSendingRssiToHost test enable the sending of RSSI range |
| 172 | | CBES setDebugAsicOutput Configure the ASIC debug output signals |
| 173 | | CBES setScanning Configure periodic scanning |
| 174 | | CBES showScanning Display periodic scanning parameters |
| 175 | | CBES setHandover Configure handover trigger |
| 176 | | CBES showHandover Display handover trigger parameters |
| 177 | | CBES showNeighborBsStat Diplay statistics of neighbor BS |
| 178 | | CBES setIotMode set IOT mode |
| 179 | | CBES showIotMode show the current IOT mode |
| 180 | | CBES enableMrctMs11 Enable MRCT MS-11.1 MS-11.2 compliance |
| 181 | | CBES enableMrctMs05 Enable MRCT MS-05.1 MS-05.2 compliance |
| 182 | | CBES setDeviceMode set DEVICE mode |
| 183 | | CBES showDeviceMode show the current DEVICE mode |
| 184 | | CBES addChannelToScanner Add a new channel to the scanning list |
| 185 | | CBES showScanner Show the the scanning list |
| 186 | | CBES removeChannelFromScanner Remove a channel from the scanning list |
| 187 | | CBES clearScannerChannels Reset all scanner entries |
| 188 | | CBES showHomeNsp Display the current home NSP |
| 189 | | CBES setHomeNsp Set the home NSP with on NSP ID |
| 190 | | CBES showProvisionedNAPs Show the list of authorized and forbidden NAPs (CAPL) |
| 191 | | CBES addProvisionedNAP Add a provisioned Nap |
| 192 | | CBES removeProvisionedNAP Remove a provisioned Nap |
| 193 | | CBES clearProvisionedNAPs Clear the list of provisioned NAPs |
| 194 | | CBES showProvisionedNSPs Show the list of authorized and forbidden NSPs |
| 195 | | CBES addProvisionedNSP Add a provisioned NSP |
| 196 | | CBES removeProvisionedNSP Remove a provisioned NSP |
| 197 | | CBES clearProvisionedNSPs Clear the list of provisioned NSPs |
| 198 | | CBES showNdssConfig Show NDSS parameters. |
| 199 | | CBES setNdssConfig Set NDSS parameters. |
| 200 | | CBES showDurationTimeout Show scan duration timeout. |
| 201 | | CBES setDurationTimeout Set scan duration timeout. |
| 202 | | CBES showHoldingTimeout Show scan holding timeout. |
| 203 | | CBES setHoldingTimeout Set scan holding timeout. |
| 204 | | CBES forceScanning Forces scanning when NDSS is in Zzz mode |
| 205 | | CBES connect Forces connection to BS |
| 206 | | CBES showPlatform Show the configuration of the platform |
| 207 | | CBES setWatchDog Enable or Disable watchdog |
| 208 | | CBES showWatchDog Show watchdog status |
| 209 | | }}} |
| 210 | | |