== !AmariSoft LTE == [[Include(Documentation/Short/Prereq)]] The image used for this experiment is 'baseline.ndz'. In this tutorial we will use nodes equipped with Netgear AC341u LTE dongles. The basestation is Amarisoft running on Bsc03out. You will run the following commands on node7-1.grid.orbit-lab.org After connecting to the grid console: 1. {{{ omf load -i baseline.ndz -t node7-1.grid.orbit-lab.org }}} 1. {{{ ssh root@node7-1.grid.orbit-lab.org }}} 1. {{{ modprobe GobiSerial }}} 1. {{{ modprobe GobiNet }}} 1. {{{ minicom -D /dev/ttyUSB1 }}} 1. {{{ AT!ippassthrough? }}} 1. It should return 1 1. If it does not, run {{{ AT!ippassthrough=1 }}} then {{{ AT!reset }}} 1. {{{ AT!entercnd="A710" }}} 1. You should see {{{ OK }}} 1. {{{ AT!dxcfg=wwan,connect,11 }}} 1. You should see {{{ OK }}} then {{{ $QCRMCALL: 1, V4 }}} 1. {{{ at!gstatus? }}} 1. Will return a status like: {{{ at!gstatus? !GSTATUS: Current Time: 10049 Temperature: 42 Bootup Time: 0 Mode: ONLINE System mode: LTE PS state: Attached LTE band: B25 LTE bw: 10 MHz LTE Rx chan: 8365 LTE Tx chan: 26365 EMM state: Registered Normal Service RRC state: RRC Connected IMS reg state: No Srv RSSI (dBm): -83 Tx Power: 0 RSRP (dBm): -117 TAC: 0001 (1) RSRQ (dB): -10 Cell ID: 01A2D001 (27447297) SINR (dB): 1.6 }}} 1. Exit Minicom by pressing Ctrl+A and then x, then enter to select ok. 1. Run {{{ dhcpcd eth2 }}} and the enter to get a new line. 1. You should get an address in the 192.168.3.0/24 subnet. 1. {{{ Ping 192.168.3.1 }}} 1. You have successfully communicated with the basestation. 1. {{{iperf -c 192.168.3.1 }}} 1. This will report your bandwidth to the basestation.